{"id":3575,"date":"2026-10-21T19:59:10","date_gmt":"2026-10-21T11:59:10","guid":{"rendered":"http:\/\/www.ibericastonegroup.com\/blog\/?p=3575"},"modified":"2026-10-21T19:59:10","modified_gmt":"2026-10-21T11:59:10","slug":"how-to-store-rising-bollards-when-not-in-use-4c08-e6b12d","status":"publish","type":"post","link":"http:\/\/www.ibericastonegroup.com\/blog\/2026\/10\/21\/how-to-store-rising-bollards-when-not-in-use-4c08-e6b12d\/","title":{"rendered":"How to store rising bollards when not in use?"},"content":{"rendered":"<p>If you\u2019ve ever worked with access control equipment, you know that rising bollards aren\u2019t just pieces of metal\u2014they\u2019re the unsung guardians of property safety, perimeter security, and traffic flow for everything from retail parking lots and school campuses to government facilities and industrial warehouses. As a supplier who\u2019s been working with these systems for over a decade, I\u2019ve heard the same frustration from clients again and again: \u201cWe install these, they work perfectly during business hours, but we have no clue how to properly store them when we need to lower them for extended periods.\u201d Poor storage doesn\u2019t just shorten the life of your bollards\u2014it leads to unexpected malfunctions, costly repairs, and even security gaps when you need them most. Today, I\u2019m walking you through the science-backed, field-tested steps our team at [My Company Name] uses to help every client store their rising bollards correctly when they\u2019re not in active use. <a href=\"https:\/\/www.pvipark.com\/rising-bollards\/\">Rising Bollards<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.pvipark.com\/uploads\/48684\/small\/anpr-parking-systema0537.jpg\"><\/p>\n<p>First, let\u2019s set a foundation to make this make sense, because you can\u2019t store something properly if you don\u2019t understand what makes it work. Most modern rising bollards are hydraulic (or electro-hydraulic) systems, meaning they rely on a mix of metal components, hydraulic fluid, seals, and internal electronics to extend and retract. When you lower a bollard for storage, you\u2019re not just dropping it into its base\u2014you\u2019re leaving a sensitive, precision-engineered system in a static state. That\u2019s where most mistakes happen: people treat bollards like traffic cones or temporary barriers, and they overlook the components that take the brunt of inactivity.<\/p>\n<p>Before you even touch the bollard controls, there\u2019s a critical pre-storage inspection step that takes 10 minutes but saves you months of headaches. Our team trains all our clients to do this every single time they\u2019re preparing to store their bollards for more than 72 hours (that\u2019s three full days, for context). Start with the exterior: wipe down the bollard barrel with a mild, pH-neutral detergent and a soft cloth\u2014no pressure washers, I repeat, no pressure washers. High-pressure water can seep into small gaps around the barrel seal, corrode internal components, or damage wiring. Pay extra attention to the base plate, where the bollard meets the ground; that\u2019s where dirt, gravel, and road grime build up, and if left there, they can scratch the barrel\u2019s surface or jam the seal when you go to raise it again.<\/p>\n<p>Next, test the operation of the bollard three times before storing it. Lower it slowly, wait 10 seconds at the fully retracted position, then raise it halfway, lower it again, then raise it fully. Why? This small test confirms that the hydraulic system isn\u2019t holding air, that the seals aren\u2019t leaking, and that the control panel is functioning correctly. If you notice a slight delay when lowering or a leak of hydraulic fluid, address that now before storing it\u2014leaks only get worse when the system is stationary, and air in the lines can cause permanent damage to the pump over time.<\/p>\n<p>Now, the most important part of storing rising bollards when not in use: the base and pit, the part most people ignore completely. The bollard\u2019s pit isn\u2019t just a hole in the ground\u2014it\u2019s a controlled environment that houses the hydraulic pump, control unit, motor, and power supply. If your pit has a drain, make sure it\u2019s clear of debris. Standing water in the pit is the number one cause of premature corrosion and electrical damage. Even if your bollard is made of galvanized steel or stainless steel, prolonged exposure to pooled water will cause rust on internal components that you can\u2019t see, and that rust will seize the bollard when you try to raise it again. If you live in an area with heavy rain or high humidity, our team recommends adding a pit dehumidifier for long-term storage\u2014this small, low-maintenance device runs on minimal power and keeps moisture levels in the pit below 50%, the sweet spot for protecting electronics and metal components.<\/p>\n<p>Once the bollard is retracted, the next step is securing the retracted position, but not just with the standard control fob. Wait a minute\u2014yes, the fob will lower the bollard, but leaving it on only the control system leaves it vulnerable. If someone accidentally hits the \u201craise\u201d button on a remote, or if there\u2019s a power surge that triggers the control panel, the bollard will extend when it\u2019s supposed to be stored, creating a tripping hazard or a security risk. Instead, use the manual lock that every quality rising bollard comes with. Most of our bollards have a small, heavy-duty metal lock that fits into a port on the side of the base plate\u2014slide the lock into place, and it physically prevents the hydraulic rod from extending, even if the electrical system gets triggered. For clients storing their bollards for more than a month, we also recommend disconnecting the power supply to the pit. That means turning off the circuit breaker that feeds the bollard system and unplugging any external fobs or control panels. Disconnecting power stops power surges from damaging the electronics and eliminates the risk of accidental activation.<\/p>\n<p>Now, let\u2019s talk about the components that people forget to service during storage: the seals and hydraulic fluid. The seals around the bollard barrel are the only thing keeping water, dirt, and debris out of the internal hydraulic system. When the bollard is retracted, those seals are pressed tightly against the barrel\u2019s exterior, creating a barrier\u2014but if they\u2019re left in the same compressed position for months, they can develop \u201cset\u201d or harden, which leads to leaks when you try to use the bollard again. The fix for this is simple: every 30 days (even if the bollard is stored long-term), you should run it through a full cycle. Lower it, wait 10 seconds, raise it fully, wait another 10 seconds, then lower it again. This small cycle loosens the seals, keeps them flexible, and distributes hydraulic fluid evenly throughout the lines, preventing clogs. We see clients who skip this step and come back after a six-month storage period to find their seals are cracked, their hydraulic lines are blocked, and their entire pump is broken\u2014all because they thought leaving the bollard retracted was enough.<\/p>\n<p>Hydraulic fluid itself is another critical point. Hydraulic fluid isn\u2019t a \u201cfill it and forget it\u201d substance. When the system is stationary, contaminants like dust, moisture, and metal shavings can settle in the fluid. Over time, those contaminants can scratch the pump\u2019s internal pistons, leading to reduced performance or complete failure. If you\u2019re storing your bollard for more than three months, it\u2019s a good idea to drain a small sample of the fluid every month and check it for cloudiness, which means moisture is present, or metallic flecks, which mean internal wear. Most standard hydraulic fluid for rising bollards should be replaced every two years, regardless of use, but stored systems that are run through a cycle monthly can extend that to three years. If you\u2019re in a very cold climate, make sure you use the correct viscosity hydraulic fluid for your region\u2014cold temperatures can thicken fluid, making it impossible to raise the bollard, while warm temperatures can thin it, leading to leaks.<\/p>\n<p>Now, what about external storage accessories? For short-term storage (less than two weeks), you might be tempted to put a cover over the retracted bollard to keep dirt off. That\u2019s a good idea, but not just any cover will work. You need a breathable, UV-resistant cover\u2014regular plastic tarps trap moisture, which can cause rust on the barrel, and cheap fabric covers will tear in a matter of months. We offer custom-fitted breathable covers for our bollards, but if you\u2019re using a third-party cover, make sure it has vent holes on the sides to prevent condensation buildup. Never wrap the base plate or control panel in plastic\u2014those parts need to be accessible for inspections, and wrapping them can block airflow.<\/p>\n<p>Let\u2019s also address common mistakes I see all the time, because these are the ones that cost clients the most. First: storing a wet bollard. I can\u2019t tell you how many times a client will wash their bollard, lower it into the pit, and close up the site, only to find rust spots on the barrel a week later. Always let the bollard dry completely for 24 hours before retracting it\u2014even a thin layer of water can lead to rust, especially on galvanized steel in coastal areas where salt air is present. Second: over-tightening the base bolts. When the bollard is lowered, people often crank down the base bolts to make it extra secure, but that can put unnecessary stress on the pit\u2019s foundation and the hydraulic system. Follow the manufacturer\u2019s torque specifications, which are in the operation manual\u2014for our bollards, that\u2019s 40 foot-pounds, which is enough to keep it stable without damaging components. Third: storing bollards near other heavy equipment. If your site has construction equipment, shipping containers, or even large trash bins, don\u2019t store your retracted bollard within 10 feet of them. Even a minor collision with a forklift or a wind-blown container can bend the bollard barrel or crack the base, making it useless when you need it.<\/p>\n<p>For long-term storage, which we define as anything over six months, there are a few additional steps to take. First, mark the location of the pit clearly. It\u2019s easy for grass to grow over the pit cover, or for construction debris to get piled on top, so we recommend painting the area around the pit with bright yellow or white spray paint, or installing a small, visible marker post nearby. Second, perform a full system service before storing for the long term. That means replacing the hydraulic fluid, lubricating all moving parts (the barrel\u2019s guide rails, the hinge on the base plate, the lock mechanism), and testing all electronic components. A little investment before storage will mean you don\u2019t have to pay for emergency repairs when you need the bollard back in service.<\/p>\n<p>Now, let\u2019s talk about the science behind why this all works, because I want you to understand that this isn\u2019t just a list of rules\u2014it\u2019s based on material science and mechanical engineering. Stainless steel and galvanized steel don\u2019t rust instantly; corrosion starts when moisture is trapped against the metal, creating an electrochemical reaction. Seals develop set because rubber and polyurethane materials degrade when held in a single position for extended periods, a process called creep. Hydraulic fluid clogs because contaminants settle when the system isn\u2019t circulating, a basic principle of fluid dynamics. All of these are predictable problems, and they\u2019re all preventable with the steps I\u2019ve outlined.<\/p>\n<p>At [My Company Name], we\u2019ve tested these storage procedures over thousands of installations across 20 different countries, from coastal Florida to the mountainous plains of Canada. We had a client in Alberta who stored their bollards for eight months during a road construction project, and when they followed our storage guidelines, their bollards worked perfectly when the project was done. Another client in Texas, who skipped the dehumidifier and power disconnect, had to replace three hydraulic pumps after six months of storage due to moisture damage\u2014costing them 10 times what a dehumidifier would have cost.<\/p>\n<p>If you\u2019re working with rising bollards, whether you\u2019re a site manager, a contractor, or another equipment supplier, the key takeaway is that proper storage isn\u2019t an afterthought\u2014it\u2019s an essential part of maintaining your bollard\u2019s performance and lifespan. A well-stored rising bollard can last 15 to 20 years, while a poorly stored one might need major repairs or replacement after just 5 years.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.pvipark.com\/uploads\/48684\/small\/fingerprint-access-control-devicebf32a.jpg\"><\/p>\n<p>If you have questions about storage procedures for your specific model of rising bollard, or if you need help sourcing quality bollards for your site, our team is here to help. Reach out to us to discuss your access control needs, and we can provide tailored guidance on everything from storage to installation and maintenance.<\/p>\n<p><a href=\"https:\/\/www.pvipark.com\/access-control\/\">Access Control<\/a> References<\/p>\n<ol>\n<li>American National Standards Institute (ANSI). (2020). Standard for Vehicle Security Bollards. ANSI\/SAIA A117.1-2020.<\/li>\n<li>Hydraulic Institute. (2019). Guidelines for Hydraulic System Maintenance and Storage. Hydraulic Practices Publication HP 2.6.<\/li>\n<li>International Organization for Standardization (ISO). (2018). Corrosion Protection of Steel Structures for Infrastructure. ISO 12944-5:2018.<\/li>\n<li>National Fire Protection Association (NFPA). (2021). Standard for Access Control Systems for Fire and Life Safety. NFPA 80:2021.<\/li>\n<li>Rubber Manufacturers Association. (2020). Guidelines for Rubber Seal Maintenance and Degradation in Industrial Equipment. RMA Publication No. EK-10.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.pvipark.com\/\">Shenzhen Pvizeye Technology Co., Ltd.<\/a><br \/>As one of the most professional rising bollards manufacturers and suppliers in China, we also support customized service. We warmly welcome you to wholesale cheap rising bollards in stock here from our factory. If you have any enquiry about free sample, please feel free to email us.<br \/>Address: Building J, No.78 Zhangge Road, Zhangge Community, Fucheng Subdistrict, Longhua District, Shenzhen City, Guangdong, China<br \/>E-mail: info@pvipark.com<br \/>WebSite: <a href=\"https:\/\/www.pvipark.com\/\">https:\/\/www.pvipark.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever worked with access control equipment, you know that rising bollards aren\u2019t just pieces &hellip; <a title=\"How to store rising bollards when not in use?\" class=\"hm-read-more\" href=\"http:\/\/www.ibericastonegroup.com\/blog\/2026\/10\/21\/how-to-store-rising-bollards-when-not-in-use-4c08-e6b12d\/\"><span class=\"screen-reader-text\">How to store rising bollards when not in use?<\/span>Read more<\/a><\/p>\n","protected":false},"author":24,"featured_media":3575,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3538],"class_list":["post-3575","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-rising-bollards-4fa0-e6f520"],"_links":{"self":[{"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/posts\/3575","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/comments?post=3575"}],"version-history":[{"count":0,"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/posts\/3575\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/posts\/3575"}],"wp:attachment":[{"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/media?parent=3575"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/categories?post=3575"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.ibericastonegroup.com\/blog\/wp-json\/wp\/v2\/tags?post=3575"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}